87 research outputs found

    Semiautomatic mammographic parenchymal patterns classification using multiple statistical features.

    Get PDF
    RATIONALE AND OBJECTIVES: Our project was to investigate a complete methodology for the semiautomatic assessment of digital mammograms according to their density, an indicator known to be correlated to breast cancer risk. The BI-RADS four-grade density scale is usually employed by radiologists for reporting breast density, but it allows for a certain degree of subjective input, and an objective qualification of density has therefore often been reported hard to assess. The goal of this study was to design an objective technique for determining breast BI-RADS density. MATERIALS AND METHODS: The proposed semiautomatic method makes use of complementary pattern recognition techniques to describe manually selected regions of interest (ROIs) in the breast with 36 statistical features. Three different classifiers based on a linear discriminant analysis or Bayesian theories were designed and tested on a database consisting of 1408 ROIs from 88 patients, using a leave-one-ROI-out technique. Classifications in optimal feature subspaces with lower dimensionality and reduction to a two-class problem were studied as well. RESULTS: Comparison with a reference established by the classifications of three radiologists shows excellent performance of the classifiers, even though extremely dense breasts continue to remain more difficult to classify accurately. For the two best classifiers, the exact agreement percentages are 76% and above, and weighted kappa values are 0.78 and 0.83. Furthermore, classification in lower dimensional spaces and two-class problems give excellent results. CONCLUSION: The proposed semiautomatic classifiers method provides an objective and reproducible method for characterizing breast density, especially for the two-class case. It represents a simple and valuable tool that could be used in screening programs, training, education, or for optimizing image processing in diagnostic tasks

    Search of low-contrast liver lesions in abdominal CT: the importance of scrolling behavior.

    Get PDF
    Purpose: Visual search using volumetric images is becoming the standard in medical imaging. However, we do not fully understand how eye movement strategies mediate diagnostic performance. A recent study on computed tomography (CT) images showed that the search strategies of radiologists could be classified based on saccade amplitudes and cross-quadrant eye movements [eye movement index (EMI)] into two categories: drillers and scanners. Approach: We investigate how the number of times a radiologist scrolls in a given direction during analysis of the images (number of courses) could add a supplementary variable to use to characterize search strategies. We used a set of 15 normal liver CT images in which we inserted 1 to 5 hypodense metastases of two different signal contrast amplitudes. Twenty radiologists were asked to search for the metastases while their eye-gaze was recorded by an eye-tracker device (EyeLink1000, SR Research Ltd., Mississauga, Ontario, Canada). Results: We found that categorizing radiologists based on the number of courses (rather than EMI) could better predict differences in decision times, percentage of image covered, and search error rates. Radiologists with a larger number of courses covered more volume in more time, found more metastases, and made fewer search errors than those with a lower number of courses. Our results suggest that the traditional definition of drillers and scanners could be expanded to include scrolling behavior. Drillers could be defined as scrolling back and forth through the image stack, each time exploring a different area on each image (low EMI and high number of courses). Scanners could be defined as scrolling progressively through the stack of images and focusing on different areas within each image slice (high EMI and low number of courses). Conclusions: Together, our results further enhance the understanding of how radiologists investigate three-dimensional volumes and may improve how to teach effective reading strategies to radiology residents

    Mass detection on mammograms: signal variations and performance changes for human and model observers

    Get PDF
    We studied the influence of signal variability on human and model observer performances for a detection task with mammographic backgrounds and computer generated clustered lumpy backgrounds (CLB). We used synthetic yet realistic masses and backgrounds that have been validated by radiologists during previous studies, ensuring conditions close to the clinical situation. Four trained non-physician observers participated in two-alternative forced-choice (2-AFC) experiments. They were asked to detect synthetic masses superimposed on real mammographic backgrounds or CLB. Separate experiments were conducted with sets of benign and malignant masses. Results under the signal-known-exactly (SKE) paradigm were compared with signal-known-statistically (SKS) experiments. In the latter case, the signal was chosen randomly for each of the 1,400 2-AFC trials (image pairs) among a set of 50 masses with similar dimensions, and the observers did not know which signal was present. Human observers' results were then compared with model observers (channelized Hotelling with Difference-of-Gaussian and Gabor channels) in the same experimental conditions. Results show that the performance of the human observers does not differ significantly when benign masses are superimposed on real images or on CLB with locally matched gray level mean and standard deviation. For both benign and malignant masses, the performance does not differ significantly between SKE and SKS experiments, when the signals' dimensions do not vary throughout the experiment. However, there is a performance drop when the SKS signals' dimensions vary from 5.5 to 9.5 mm in the same experiment. Noise level in the model observers can be adjusted to reproduce human observers' proportion of correct answers in the 2-AFC task within 5% accuracy for most condition

    "Migrants, States, and EU Citizenship's Unfulfilled Promise"

    Get PDF
    A constant aim of EU citizenship, and indeed the entire project of European integration, has always been to lower barriers and create a common space. If the complete elimination of national borders remains elusive, their importance has been diminished in striking ways by the development of EU citizenship and the ban against nationality based discrimination. Yet the barriers to free movement have been lowered in differential ways. Most citizens of EU member states now enjoy residence, employment and other rights throughout Europe. The extension of some rights to some categories of citizens of some new member states is admittedly sometimes subject to transition periods, but these expire. By contrast, third country nationals -- individuals who do not hold citizenship of one of the member states, even though they may have resided for many years, or even been born in Europe -- remain largely excluded from the benefits of EU citizenship. Various initiatives over the years have opened up limited rights for third country nationals. But the difficulty of enacting these rights, and current moves to more restrictive immigration and naturalization policies, highlight the continuing exclusivity of EU citizenship: immigrants migrate to national polities, and they become European only by virtue of incorporation into national states. This means that EU citizenship's transformative potential remains unrealized.Glendon College (York University

    Measurement of the azimuthal anisotropy of Y(1S) and Y(2S) mesons in PbPb collisions at √S^{S}NN = 5.02 TeV

    Get PDF
    The second-order Fourier coefficients (υ2_{2}) characterizing the azimuthal distributions of Υ(1S) and Υ(2S) mesons produced in PbPb collisions at sNN\sqrt{s_{NN}} = 5.02 TeV are studied. The Υmesons are reconstructed in their dimuon decay channel, as measured by the CMS detector. The collected data set corresponds to an integrated luminosity of 1.7 nb1^{-1}. The scalar product method is used to extract the υ2_{2} coefficients of the azimuthal distributions. Results are reported for the rapidity range |y| < 2.4, in the transverse momentum interval 0 < pT_{T} < 50 GeV/c, and in three centrality ranges of 10–30%, 30–50% and 50–90%. In contrast to the J/ψ mesons, the measured υ2_{2} values for the Υ mesons are found to be consistent with zero

    Measurement of prompt D0^{0} and D\overline{D}0^{0} meson azimuthal anisotropy and search for strong electric fields in PbPb collisions at root SNN\sqrt{S_{NN}} = 5.02 TeV

    Get PDF
    The strong Coulomb field created in ultrarelativistic heavy ion collisions is expected to produce a rapiditydependent difference (Av2) in the second Fourier coefficient of the azimuthal distribution (elliptic flow, v2) between D0 (uc) and D0 (uc) mesons. Motivated by the search for evidence of this field, the CMS detector at the LHC is used to perform the first measurement of Av2. The rapidity-averaged value is found to be (Av2) = 0.001 ? 0.001 (stat)? 0.003 (syst) in PbPb collisions at ?sNN = 5.02 TeV. In addition, the influence of the collision geometry is explored by measuring the D0 and D0mesons v2 and triangular flow coefficient (v3) as functions of rapidity, transverse momentum (pT), and event centrality (a measure of the overlap of the two Pb nuclei). A clear centrality dependence of prompt D0 meson v2 values is observed, while the v3 is largely independent of centrality. These trends are consistent with expectations of flow driven by the initial-state geometry. ? 2021 The Author. Published by Elsevier B.V. This is an open access article under the CC BY licens

    Measurement of the Y(1S) pair production cross section and search for resonances decaying to Y(1S)μ⁺μ⁻ in proton-proton collisions at √s = 13 TeV

    Get PDF
    The fiducial cross section for Y(1S)pair production in proton-proton collisions at a center-of-mass energy of 13TeVin the region where both Y(1S)mesons have an absolute rapidity below 2.0 is measured to be 79 ± 11 (stat) ±6 (syst) ±3 (B)pbassuming the mesons are produced unpolarized. The last uncertainty corresponds to the uncertainty in the Y(1S)meson dimuon branching fraction. The measurement is performed in the final state with four muons using proton-proton collision data collected in 2016 by the CMS experiment at the LHC, corresponding to an integrated luminosity of 35.9fb1^{-1}. This process serves as a standard model reference in a search for narrow resonances decaying to Y(1S)μ+^{+}μ^{-} in the same final state. Such a resonance could indicate the existence of a tetraquark that is a bound state of two bquarks and two b̅ antiquarks. The tetraquark search is performed for masses in the vicinity of four times the bottom quark mass, between 17.5 and 19.5GeV, while a generic search for other resonances is performed for masses between 16.5 and 27GeV. No significant excess of events compatible with a narrow resonance is observed in the data. Limits on the production cross section times branching fraction to four muons via an intermediate Y(1S)resonance are set as a function of the resonance mass
    corecore